All about instantaneous water heaters! >
×

E-compact instant water heater
CEX-U (CX2)

E-compact instant water heater CEX-U (CX2)

Energy efficiency class A

(Scale: A+ to F)

  • CEX-U: 11/13.5 kW, 400 V
  • CEX-U (13,5 kW)

This is where the CEX-U is used.

  1. Kitchen sink

    Kitchen sink

  2. Washstand

    Washstand

  3. Double washbasin

    Double washbasin

Precise hot water convenience.

The CEX-U’s electronic controls ensure an energy-efficient hot water supply. The water is heated directly to the preset temperature while flowing though the unit. The temperature is selected by pushing one of the buttons on the LCD panel, with factory settings programmed at 35 °C and 48 °C.

  • Electronically controlled instant water heater in compact design for installation under the sink
  • Push-button operation panel with LCD display for precise temperature setting between 20 °C and 60 °C
  • In the comfort zone between 35 °C and 43 °C, the temperature can be set in 0.5 degree increments
  • Two programming buttons for  individual pre-set ­temperatures, optional temperature limitation as well as function indicators
  • Adding cold water is no longer necessary
  • Easy installation under the kitchen sink facilitated by small dimensions and external ⅜" water connectors for closed-outlet or open-outlet installation
  • With power cable for permanent electrical connection
  • Precise temperatures due to TWIN TEMPERATURE control TTC® up to the capacity of the appliance
  • With the Multiple Power System MPS®, the maximum power rating is set at the time of installation
  • Remote control module available as an accessory: FX wireless remote control
  • Dimensions (height × width × depth): 29.4 × 17.7 × 10.8 cm

Technical data

>

Data. Values. Facts.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
E-compact instant water heater CEX-U E-compact instant water heater CEX-U (13,5 kW)
Kitchen sink Washstand Double washbasin Kitchen sink Washstand Double washbasin
CEX-U CEX-U (13,5 kW)
Part number
Nominal power rating 1) (variably adjustable due to MPS) at 400 V [kW]
Maximum operating pressure [MPa (bar)]
Water connections (thread connections)
Hot water output at Δt = 33 K 2) [l/min]
Switch-on flow rate [l/min]
Maximum flow rate 3) [l/min]
Supply voltage [3~ / PE 380–415 V AC] Permanent connection
Nominal current at 400 V [A]
Required cable diameter [mm²]
Maximum inlet temperature [°C]
Solar-ready 4)
Protection class
Specific water resistance at 15 °C [Ωcm] ≥
Weight filled with water [kg], approx.
2400-26213 2400-26413
11.0 13.5
1 (10) 1 (10)
G ⅜" G ⅜"
4.8 5.8
2 2
5 5
16 20
1.5 2.5
60 60
IP 24 IP 24
1000 1000
2.7 2.7

1) The selected power rating determines the values of nominal current, cable diameter and hot water output

2) Temperature increase e.g. from 12 °C to 45 °C (mixed water at flow rate >5 l/min)

3) Limited flow amount for optimal temperature increase

4) Suitable for reheating

Downloads

>

Media type Title Date Size

Product information sheet

CEX-U-(CX2)-PI-en.pdf

13.07.2021

> download
Product information sheet CEX-U-(CX2)-PI-en.pdf 13.07.2021 1,6 MB
> download

Operating instructions

CEXU-CEX-CEX9U-CEX9-GA-de-en-fr-nl-pt-es-pl-sv-cs-sk.pdf

06.06.2023

> download
Operating instructions CEXU-CEX-CEX9U-CEX9-GA-de-en-fr-nl-pt-es-pl-sv-cs-sk.pdf 06.06.2023 6,2 MB
> download
  Older versions> 
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-de-en-fr-nl-pt-es-pl-sv-cs-sk-11-2021.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-de-en-fr-nl-pt-es-pl-sv-cs-sk-05-2020.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-v2.2-GA-de-en-fr-nl-pt-es-pl-sv-cs-sk-09-2018.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-10-Sprachen-06-2016.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-10-Sprachen-05-2016.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-10-Sprachen-v2.1-06-2015.pdf> download> download
 Operating instructionsCEXU-CEX-CEX9U-CEX9-GA-10-Sprachen-v2.1-04-2015.pdf> download> download
  Further versions on request 

Installation instructions

CEXU-MA-de-en-fr-nl-pt-es-pl-sv-cs-sk.pdf

05.11.2021

> download
Installation instructions CEXU-MA-de-en-fr-nl-pt-es-pl-sv-cs-sk.pdf 05.11.2021 9,9 MB
> download
  Older versions> 
 Installation instructionsCEXU-MA-de-en-fr-nl-pt-es-pl-sv-cs-sk-06-2021.pdf> download> download
 Installation instructionsCEXU-v2.2-MA-de-en-fr-nl-pt-es-pl-sv-cs-sk-05-2020.pdf> download> download
 Installation instructionsCEXU-v2.2-MA-de-en-fr-nl-pt-es-pl-sv-cs-sk-09-2018.pdf> download> download
 Installation instructionsCEXU-MA-10-Sprachen-08-2017.pdf> download> download
 Installation instructionsCEXU-MA-10-Sprachen-08-2016.pdf> download> download
 Installation instructionsCEXU-MA-10-Sprachen-v2.1-08-2015.pdf> download> download
 Installation instructionsCEXU-MA-10-Sprachen-v2.1-06-2015.pdf> download> download
 Installation instructionsCEXU-MA-10-Sprachen-v2.1-05-2015.pdf> download> download
  Further versions on request 

Operating and installation instructions

CX2-DX2-Beiblatt-60Grad-de-en-fr-nl-pt-es-pl-sv-cs-sk-03-2021.pdf

31.03.2021

> download
Operating and installation instructions CX2-DX2-Beiblatt-60Grad-de-en-fr-nl-pt-es-pl-sv-cs-sk-03-2021.pdf 31.03.2021 29 kB
> download

Safety instructions

Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf

19.03.2021

> download
Safety instructions Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf 19.03.2021 483 kB
> download

Energy label

CEX-U-Energielabel.pdf

13.02.2017

> download
Energy label CEX-U-Energielabel.pdf 13.02.2017 220 kB
> download

ErP product sheet

CEX-CEX-U-CEX9-CEX9-U-ErP-Produktdatenblatt.pdf

13.02.2017

> download
ErP product sheet CEX-CEX-U-CEX9-CEX9-U-ErP-Produktdatenblatt.pdf 13.02.2017 234 kB
> download

CE Conformity

CE-Konformitaetserklaerung-nach-RED+RoHS3-CX-2021-09.pdf

05.11.2021

> download
CE Conformity CE-Konformitaetserklaerung-nach-RED+RoHS3-CX-2021-09.pdf 05.11.2021 752 kB
> download

Product photo

CEX-U_frontal-HighRes.jpg

11.05.2017

> download
Product photo CEX-U_frontal-HighRes.jpg 11.05.2017 531 kB
> download

Product photo

CEX-U_links-HighRes.jpg

11.05.2017

> download
Product photo CEX-U_links-HighRes.jpg 11.05.2017 550 kB
> download

Product photo

CEX-U_rechts-HighRes.jpg

11.05.2017

> download
Product photo CEX-U_rechts-HighRes.jpg 11.05.2017 570 kB
> download

Image photo

CEX-U-Milieufoto.jpg

11.05.2017

> download
Image photo CEX-U-Milieufoto.jpg 11.05.2017 272 kB
> download

Catalogue

CLAGE-Instantaneous-water-heater-Catalogue-en.pdf

20.06.2023

> download
Catalogue CLAGE-Instantaneous-water-heater-Catalogue-en.pdf 20.06.2023 21,7 MB
> download

Catalogue

CLAGE-Brochure-en.pdf

31.01.2023

> download
Catalogue CLAGE-Brochure-en.pdf 31.01.2023 5,7 MB
> download

BIM

CEXU-002-BIM.rfa

16.04.2018

> download
BIM CEXU-002-BIM.rfa 16.04.2018 1,2 MB
> download

BIM

CEX13U-001-BIM.ifc

16.04.2018

> download
BIM CEX13U-001-BIM.ifc 16.04.2018 2,2 MB
> download

BIM

CEX11U-001-BIM.ifc

16.04.2018

> download
BIM CEX11U-001-BIM.ifc 16.04.2018 2,2 MB
> download

Datanorm

Datanorm.zip

05.02.2021

> download
Datanorm Datanorm.zip 05.02.2021 17,0 MB
> download

GAEB

GAEB.zip

25.11.2020

> download
GAEB GAEB.zip 25.11.2020 36 kB
> download

Accessories

>

FVS

FVS (included)

Flexible connecting hose ⅜ inch cap nut × ⅜ inch cap nut, length 50 cm

FVS: Part no. 89620

T-piece

T-piece (included)

Special T-connector ⅜ inch cap nut × ⅜ inch angle valve 10 mm

T-piece: Part no. 89610

CSP 6

CSP 6 (optional)

Aerator insert for tap adapter M 22/24 at the tap. The aerator at the tap supports the energy- and water-saving operation of the compact instant water heater. The new special CSP aerators mix air into the water and thus create a uniform water stream that does not splatter but softly cascades down. CSP 6 (< 3,5 l/min).

CSP 6: Part no. 0010-00461

CSP 6a

CSP 6a (optional)

Aerator with chrome tap adapter M 24a (suitable for taps with internal thread at outlet). The aerator at the tap supports the energy- and water-saving operation of the compact instant water heater. The new special CSP aerators mix air into the water and thus create a uniform water stream that does not splatter but softly cascades down. CSP 6a (< 3,5 l/min).

CSP 6a: Part no. 0010-0047

CSP 6i

CSP 6i (optional)

Aerator with chrome tap adapter M 22i (suitable for taps with external thread at outlet). The aerator at the tap supports the energy- and water-saving operation of the compact instant water heater. The new special CSP aerators mix air into the water and thus create a uniform water stream that does not splatter but softly cascades down. CSP 6i (< 3,5 l/min).

CSP 6i: Part no. 0010-0046

EAK

EAK (optional)

Single-lever mixer tap with side lever and swivel spout 20 cm

EAK: Part no. 1100-04430

EKA

EKA (optional)

Single-lever mixer tap with pull-out rinse sprayer and flexible connecting hoses, spout 20 cm

EKA: Part no. 1100-04230

FX

FX (optional)

- FOR DEVICES YEAR OF CONSTRUCTION 2017 to 2021 ONLY - Remote control including transmission unit FXE for installation into the instantaneous water heater. In addition to user controls directly at the unit, the remote control allows for convenient temperature adjustment of the instant water heater at interior distances of up to 10 meters. Secure, bidirectional wireless transfer, continuous two-button temperature selection, two pre-set buttons and a LCD display, magnetic wall holder and ­batteries (included). IP 20. Dimensions (H × W × D): 5.8 × 12.5 × 1.9 cm

FX: Part no. 2400-26090

FX (until 2016)

FX (until 2016) (optional)

– ONLY FOR DEVICES BUILT UNTIL END OF 2016 – Remote control including transmission unit FXE for installation into the instantaneous water heater. In addition to user controls directly at the unit, the remote control allows for convenient temperature adjustment of the instant water heater at interior distances of up to 10 meters. Secure, bidirectional wireless transfer, continuous two-button temperature selection, two pre-set buttons and a LCD display, magnetic wall holder and ­batteries (included). IP 20. Dimensions (H × W × D): 5.8 × 12.5 × 1.9 cm

FX (until 2016): Part no. 2400-26050

LAB

LAB (optional)

Load shedding module (electrical installation kit) with pre-installed cables, contactor and load shedding relay, for joint connection of an instant water heater with an output ≤ 13,5 kW and an electromechanical cooker at a cooker terminal outlet box, if no separate outlet is available for the instant water heater. IP 55. Dimensions (H × W × D): 18 × 13 × 8 cm

LAB: Part no. 82260

Interesting features.

  1. Smart Control-ready

    Smart Control-ready

  2. Remote control (optional)

    Remote control (optional)

  3. Solar-compatible, suitable for reheating

    Solar-compatible, suitable for reheating

Installation video

Similar products:

E-compact instant water heater CEX-U
CEX-U: 11/13.5 kW, 400 V