Search MyCLAGE - Login

E-comfort instant water heater
DCX Next

E-comfort instant water heater DCX Next

Energy efficiency class A

(Scale: A+ to F)

  • DCX Next: 18/21/24/27 kW, 400 V

This is where the DCX Next is used.

  1. Handwashbasin

    Handwashbasin

  2. Shower

    Shower

  3. Bath tub

    Bath tub

  4. Kitchen sink

    Kitchen sink

Saving energy in the bathroom is that easy!

New product
The electronic E-comfort instant water heater DCX Next is designed for easy operation. One of the five typical hot water temperatures can be selected using the sensor button. Each temperature is indicated by an easily understandable colour display.

  • Electronically controlled instantaneous water heater with simple operating concept
  • One-button control panel for quick and easy temperature selection in five levels: 35 °C, 38 °C, 42 °C, 48 °C and 55 °C
  • Electronic safety system with air bubble detection, temperature and pressure shut-off
  • Temperature stable up to the power limit. TWIN TEMPERATURE Control TTC® ensures precise temperature control to the degree, even with fluctuations in water pressure.
  • With Multiple Power System MPS® the maximum power consumption is determined at installation: 18, 21, 24 or 27 kW, 400 V
  • Suitable for water-saving taps due to particularly low switch-on water quantity from 1.5 l/min thanks to innovative water flow technology
  • Dimensions (height × width × depth): 46.8 × 23.9 × 9.6 cm

Technical data

>

Data. Values. Facts.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
E-comfort instant water heater DCX Next
Handwashbasin Shower Bath tub Kitchen sink      
DCX Next
Part number
Nominal power rating 1) (variably adjustable due to MPS) [kW]
Permissible operating pressure [MPa (bar)] 2)
Water connections (thread connections)
Hot water output at Δt = 28 K 3) [l/min]
Switch-on flow rate [l/min]
Maximum flow rate 4) [l/min]
Supply voltage [3~ / PE 400 V AC] permanent connection
Required cable diameter [mm²]
Maximum inlet temperature [°C]
Protection class
Specific water resistance at 15 °C [Ωcm] ≥
Weight filled with water [kg], approx.
3200-36300
18 21 24 27
1 (10) 1 (10) 1 (10) 1 (10)
G ½" G ½" G ½" G ½"
9.2 10.7 12.3 13.8
1.5 1.5 1.5 1.5
8.0 8.0 8.0 8.0
4.0 4.0 6.0 6.0
30 30 30 30
IP 25 IP 25 IP 25 IP 25
1100 1100 1100 1100
4.2 4.2 4.2 4.2

1) The selected power rating determines the values of nominal current, cable diameter and hot water output

2) Also approved for pressureless operation

3) Temperature increase e.g. from 12 °C to 40 °C, mixed water

4) Limited flow amount for optimal temperature increase

Downloads

>

Media Title Date Size

Product information sheet

DCX13-Next-DCX-Next-PI-en.pdf

24.06.2020

> download
Product information sheet DCX13-Next-DCX-Next-PI-en.pdf 24.06.2020 730 kB
> download

Installation instructions

DCX-Next-Beiblatt-Erstinbetriebnahme-de-en.pdf

18.03.2020

> download
Installation instructions DCX-Next-Beiblatt-Erstinbetriebnahme-de-en.pdf 18.03.2020 369 kB
> download

Operating and installation instructions

DCX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf

24.07.2020

> download
Operating and installation instructions DCX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf 24.07.2020 4,0 MB
> download
  Older versions> 
 Operating and installation instructionsDCX-Next-Online-GMA-de-en-02-2020.pdf> download> download
  Further versions on request 

Quick guide

DCX-Next-KA-de-en.pdf

18.02.2020

> download
Quick guide DCX-Next-KA-de-en.pdf 18.02.2020 2,3 MB
> download

Image-only instructions

DX3-400V-BiA-mit-DMB.pdf

23.03.2020

> download
Image-only instructions DX3-400V-BiA-mit-DMB.pdf 23.03.2020 1,9 MB
> download

Installation accessories

DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf

13.11.2018

> download
Installation accessories DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf 13.11.2018 370 kB
> download

Safety instructions

Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr.pdf

29.01.2019

> download
Safety instructions Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr.pdf 29.01.2019 572 kB
> download

Energy label

DCX-Next-Energielabel.pdf

22.01.2020

> download
Energy label DCX-Next-Energielabel.pdf 22.01.2020 229 kB
> download

ErP product sheet

9120-96xxx-DX3-DCX-Next-ErP-Produktdatenblatt.pdf

22.01.2020

> download
ErP product sheet 9120-96xxx-DX3-DCX-Next-ErP-Produktdatenblatt.pdf 22.01.2020 234 kB
> download

ErP product sheet

DCX-Next-DCX13-Next-ErP-Produktdatenblatt.pdf

18.03.2020

> download
ErP product sheet DCX-Next-DCX13-Next-ErP-Produktdatenblatt.pdf 18.03.2020 66 kB
> download

CE Conformity

DX3-Konformitaetserklaerung-CE-Conformity-de-en-09-2019.pdf

24.09.2019

> download
CE Conformity DX3-Konformitaetserklaerung-CE-Conformity-de-en-09-2019.pdf 24.09.2019 159 kB
> download

Catalogue

CLAGE-Instantaneous-water-heater-Catalogue-en.pdf

13.05.2020

> download
Catalogue CLAGE-Instantaneous-water-heater-Catalogue-en.pdf 13.05.2020 17,7 MB
> download

BIM

DX3-DCX-002.ifc

12.03.2020

> download
BIM DX3-DCX-002.ifc 12.03.2020 4,8 MB
> download

BIM

DX3-DCX-002.rfa

12.03.2020

> download
BIM DX3-DCX-002.rfa 12.03.2020 4,0 MB
> download

Datanorm

Datanorm.zip

24.06.2020

> download
Datanorm Datanorm.zip 24.06.2020 39,7 MB
> download

GAEB

GAEB.zip

24.06.2020

> download
GAEB GAEB.zip 24.06.2020 377 kB
> download

Accessories

>

RDX 3

RDX 3 (optional)

If required, the universal mounting frame RDX 3 is available as an accessory, with which the electrical connection can be made at any point behind the device. The IP protection class of the device with RDX 3 is IP24. With electrical wiring and pipe extensions. For difficult installation conditions, e.g. replacement of a flow heater with different connections. Compensates for tile projections or wall unevenness. Installation only by a specialist.

RDX 3: Part no. 3200-36100

UDX

UDX (optional)

Pipe assembly for undersink installation with water connections, top flush-mounted G ⅜ inch (basic mounting kit RDX required).

UDX: Part no. 3200-34110

VDX

VDX (optional)

Pipe assembly for offset installation or reversed water connections when exchanging gas water heaters (basic mounting kit RDX required).

VDX: Part no. 3200-34120

Interesting features.

  1. Cost-saving

    Cost-saving

  2. Instantly at the right temperature

    Instantly at the right temperature

  3. More hygiene

    More hygiene

  4. Environmentally friendly

    Environmentally friendly

  5. Short water paths

    Short water paths

Installation video

Similar products:

E-comfort instant water heater DEX Next
DEX Next: 18/21/24/27 kW, 400 V
E-comfort instant water heater DCX 13 Next
DCX 13 Next: 11/13.5 kW, 400 V